P01F3
O2 Sensor Circuit High Voltage Bank 1 Sensor 4
What could P01F3 mean for your vehicle?
Add your vehicle to explore possible causes and next checks. AI guidance helps you investigate; it does not confirm a diagnosis.
P01F3 means the voltage from the oxygen sensor at bank 1 sensor 4 is higher than it should be.
Bank 1 sensor 4 is a fourth oxygen sensor on bank 1. Sensors are numbered from the engine back, so sensor 4 sits further down the exhaust than sensor 3, behind a catalytic converter. Few vehicles have one, so check the service information to find it.
A switching oxygen sensor gives about 0.1 volt when the exhaust is lean and about 0.9 volt when it is rich. A reading above the normal range usually means the signal wire is touching a powered circuit or the sensor has failed. Check the wiring first.
Severity
Symptoms
- •Check engine light on
- •Usually no change in how the engine runs
Likely Causes
Wiring that has melted or chafed against a powered circuit, such as the sensor's own heater wires, can push the signal too high.
A sensor that has failed inside can hold its output high.
Rare. Check the sensor and wiring first.
Estimated Cost
Professional Repair
Includes parts + labor
Common Fixes
- Find sensor 4 on bank 1 in the service information
- Check the connector and wiring for heat damage, chafing and corrosion
- Watch the sensor's voltage on a scan tool with the engine fully warm
- Replace the sensor if the wiring checks out
Shop Parts
Related Codes
Still have questions about P01F3?
Continue with P01F3Next: add your vehicle and symptoms. Your code carries over.