P0B46
Hybrid/EV Battery Voltage Sense C Circuit Range/Performance
What could P0B46 mean for your vehicle?
Add your vehicle to explore possible causes and next checks. AI guidance helps you investigate; it does not confirm a diagnosis.
P0B46 means the battery controller has found that the reading on hybrid battery voltage sense channel C is within its normal range but does not make sense compared with the rest of the battery. The voltage sense channels are the inputs that measure individual cells or groups of cells in the high-voltage battery.
GM, for example, compares how each cell reading moves with how the average of the other cells moves. When the average changes by more than a small amount and channel C does not move with it in the same direction, a failure is counted. Enough failures in a set number of samples set the code, and the light comes on after two trips in a row.
Chrysler numbers the channels instead of lettering them and calls this code Voltage Sense 3 Circuit Performance. On the 2020 Pacifica plug-in hybrid it can appear with several other voltage sense, contactor and precharge codes, and the listed fix is a battery pack control module software update. Any work inside the battery pack must be done by a trained technician with the high-voltage system disabled.
Severity
Symptoms
- •Check engine light on
- •May be stored along with codes for other voltage sense channels
- •On the Chrysler Pacifica plug-in hybrid, scheduled charging may not start because the battery pack does not wake up
Likely Causes
The circuit that measures channel C can hold a reading that no longer follows the real cell voltage.
A loose, corroded or damaged sense connection can stop the reading from tracking the cell.
On the 2020 Chrysler Pacifica plug-in hybrid, the maker fixed this code and several sibling codes with a battery pack control module software update.
Uncommon. Rule out software, wiring and the monitoring electronics first.
Estimated Cost
Professional Repair
Includes parts + labor
Common Fixes
- Check for a battery control module software update and reprogram the module if one applies, keeping a 12 volt charger connected during the update
- Compare the cell voltage readings in live data while the battery charges or discharges, and check whether the channel C reading moves with the others
- Have the sense wiring and the cell monitoring electronics inspected and repaired. Work inside the battery pack only by a trained technician with the high-voltage system disabled
- Clear the codes and confirm they do not return
Shop Parts
Related Codes
Still have questions about P0B46?
Continue with P0B46Next: add your vehicle and symptoms. Your code carries over.